tecned-logo-for-menupage

ONV-XP UPS

Endurance 6-10kVA

High Reliability

  • Built-in LP inductor for motor loads.
  • Wide input voltage range of -60% to +25%, showcasing remarkable adaptability to various grid conditions.
  • Strong Overload Capacity: Handles overloads effectively for stable performance.
  • Seamless Maintenance: Hot-swappable design ensures uninterrupted operation during maintenance.
  • Dual Redundant Control: Dual cards and DSP controls prevent single failure point.
  • Efficient Fan Control: Intelligent fan management and redundancy save energy, sustaining 25% load with 2 fans failed and 50% with 1 fan failed.
  • Comprehensive Protection: Integrated input, output, bypass breaker, and manual bypass enhance system safety.
  • Emergency Power-Off (EPO): Standard EPO function swiftly disconnects power during emergencies.
  • Durable PCBs: Anti-corrosion coating on all PCBs boosts longevity.
x-pnd-400-1200-kva-img_1

Green power

  • Achieves up to 97% AC/AC efficiency, even at 30% load, minimizing heat and saving power costs.
  • ECO mode offers up to 99% efficiency, reducing expenses. W-ECO mode reaches 98.5% efficiency, lowering TCO with fast transfers.
  • High input power factor (up to 0.99) and low Input THDi (< 3.0% at full load) cut grid pollution and costs.
  • Advanced and compact 3U height 100KW power module equipped with maximum 30A charger.
  • Enable self-loading test functionality for convenient debugging and on-site testing prior to real load connection. This eliminates the need for expensive temporary loads, cabling, and breakers, resulting in energy and cost savings.
x-pnd-400-1200-kva-img_2

Advanced technology

  • Three level technology ensures low harmonics, remarkable efficiency, and substantial energy conservation.
  • The Power Walk-in feature mitigates inrush current to the main power source or generator.
  • Advanced parallel expansion technology supports 8 units up to 9.6MW in parallel, single /parallel system compatible.
  • Self-dedusting function which saves the service time.
  • The Parallel ECO mode maximizes overall system efficiency during parallel operation.
  • Common battery bank on parallel mode.
  • Frequency converter function (60Hz to 50Hz or 50Hz to 60Hz)

User-friendly Interface

  • User-friendly ON/OFF – Double physical button design to avoid false operation.
  • Equipped with a 7-inch touch screen with LED Indicators, ensuring comprehensive and visualized information display.
  • Large data storage capacity,10000 entry events logs.
  • User-Friendly Interface – A friendly human-machine interface presenting data and graphical representations.
  • Hassle-free software updates on-site, enabling a singular update for all power and control modules.
  • ON/OFF – Double Button design to prevent maloperations and touch screen failure.
  • Smart programmable dry contact communication function.

Intelligent Management

  • Fault Trace Management (FTM) for convenient failure analysis (waveform record before & after of the fault point for 200ms) which easily figure out faulty point.
  • Battery Life Extension: Use a three-stage charging system to prolong battery lifespan.
  • Intelligent Battery Management: Replace faulty batteries (30-50 per string) instead of the entire set.
  • Early Warning System: Get alerted about potential faults with pre-alarm on key parts.
  • Efficient Asset Tracking: Keep track of part replacements, timelines, and service details for effective management.

Options

Battery Monitoring Solutions:

  • Advanced battery monitoring per block
    voltage, Impedance, and temperature.

Flexible Network Management:

  • Optional internal SNMP adapter
  • Customer interface software

Intelligent management software

  • Smart status diagnosis
  • Abnormal status real time alarm
  • Event logs recording
  • Parameters real time monitoring

More Options

  • Bypass voltage regulator
  • Extended dry contact card
  • BMS card for lithium battery
  • Input and output isolation transformer
  • Output Synchronization Common Bus
  • Battery Charge Temperature Compensation

ONV-XP 100-300kVA

MODEL ONV-XP 100 ONV-XP 150 ONV-XP 200 ONV-XP 250 ONV-XP 300
Power module Model XPD-50 XPD-100
Voltage Range (Vac) 3Φ4W+PE, 380/400/415, L-L: 138~485
Input Wiring 3Ph+N+PE
Input Frequency (Hz) 40-70
Bypass Voltage Range (Vac) -20% (10/15/30/40/50/60%) ~ +15% (10/20/25%)
Power Factor ≥0.99
THDi at full Linear load <3%
Output
Power Module (kW) 50kW 100kW
Power Module Number 2+1 3+1 4+1 5+1 3+1
System Capacity (kVA) 100 150 200 250 300
Power Factor 1
Voltage (Vac) 3Φ4W+PE, L-L: 380,400,415 ±1%
Frequency (Hz) 50/60 ±0.2% (battery mode)
Three Phase Difference True sine wave,≤2 degrees
THDv ≤1% (linear load, full load); ≤4% (no linear load, full load)
Static Bypass Transfer Time 0
System Efficiency (MAX) 97%
Overload Capacity 101-105% Long run, 106-110% load for 60 minutes, 111%-125% load for 10 minutes, 126%-150% load for 1 minute, over 150% load transfer to bypass
Battery
Battery Voltage (Vdc)* ±240 (±180~±300 settable)
Charging Current (A) N×30 Maximum (N = the number of power module)
Others
Display 7-inch Touch screen+ LED+ Physical buttons
Operating Temperature (ºC) 0~40
Storage Temperature (ºC) -40~70
Relative Humidity 0~95%, no condensation
Communication Function RS232, RS485, Dry contact, MODBUS, SNMP (optional)
Noise (dB) 70
Altitude (m) 0~2000, no derating
Cabling Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top
Power Module Dimension (mm) W×D×H 500×750×130(3U)
Cabinet Dimension (mm) W×D×H W:600 D:860 H:2000 W:600 D:860 H:2000 W:600 D:860 H:2000 W:600 D:860 H:2000 W:1200 D:1000 H:2000
Weight (kg) Cabinet 228 228 240 240 291
Power Module 33 33 33 33 55

ONV-XP 400-1000kVA

MODEL ONV-XP 400 ONV-XP 500 ONV-XP 600 ONV-XP 800 ONV-XP 1000
Power module Model XPD-100
Voltage Range (Vac) 3Φ4W+PE, 380/400/415, L-L: 138~485
Input Wiring 3Ph+N+PE
Input Frequency (Hz) 40-70
Bypass Voltage Range (Vac) -20% (10/15/30/40/50/60%) ~ +15% (10/20/25%)
Power Factor ≥0.99
THDi at full Linear load <3%
Output
Power Module (kW) 100
Power Module Number 4+1 5+1 6+1 8+1 10+2
System Capacity (kVA) 400 500 600 800 1000
Power Factor 1
Voltage (Vac) 3Φ4W+PE, L-L: 380,400,415 ±1%
Frequency (Hz) 50/60± 0.2% (battery mode)
Three Phase Difference True sine wave,≤2 degrees
THDv ≤1% (linear load, full load); ≤4% (no linear load, full load)
Static Bypass Transfer Time 0
System Efficiency (MAX) 97%
Overload Capacity 101-105% Long run, 106-110% load for 60 minutes, 111%-125% load for 10 minutes, 126%-150% load for 1 minute, over 150% load transfer to bypass
Battery
Battery Voltage (Vdc)* ±240 (±180~±300 settable)
Charging Current (A) N×30 Maximum (N = the number of power module)
Others
Display 7-inch Touch screen+ LED+ Physical buttons
Operating Temperature (ºC) 0~40
Storage Temperature (ºC) -40~70
Relative Humidity 0~95%, no condensation
Communication Function RS232, RS485, Dry contact, MODBUS, SNMP (optional)
Noise (dB) 70
Altitude (m) 0~2000, no derating
Cabling Bottom/Top Bottom/Top Bottom/Top Bottom/Top Bottom/Top
Power Module Dimension (mm) W×D×H 500×750×130(3U)
Cabinet Dimension (mm) W×D×H W:800 D:1000 H:2000 W:800 D:1000 H:2000 W:1400 D:1000 H:2000 W:1800 D:1000 H:2000 W:1800 D:1000 H:2000
Weight (kg) Cabinet 325 325 580 650 745
Power Module 55 55 55 55 55