Endurance UPS series, an industrial-grade UPS system that delivers reliable and continuous power protection for critical applications. With a capacity range of 10-40 kVA and true on-line double-conversion technology, our UPS system provides the highest level of power protection and ensures uninterrupted power to your equipment.
Fitted with an LP inductor-capacitor circuit, the Endurance UPS provides an extra layer of protection against electrical interference and noise, reducing peak voltage and harmonics generated by the load. The low-pass filter improves the power quality of your electrical system, which leads to better efficiency, reliability, and performance. Built with durability and reliability in mind, our UPS system is the ideal choice for industrial customers who demand high-quality power protection.
Standard LP filter in the UPS output to reduce voltage peaks and harmonics, improving the overall power quality in the load.
Trust the Endurance UPS to keep your equipment running smoothly and protect you from costly downtime.
TECNED UPS MODEL | EN 10 | EN 15 | EN 20 | EN 30 | EN 40 |
Input | |||||
Voltage (Vac) | 150-280 (L-N) 1W+ N+PE or 260-485 (L-L) 3W+ N+PE | 260-485 (L-L) 3W+ N+PE | |||
Frequency (Hz) | 40-70 | ||||
Power Factor | ≥ 0.99 | ||||
THDi | < 5% | ||||
Output | |||||
Capacity (kVA) | 10 | 15 | 20 | 30 | 40 |
AC/AC Efficiency | Up to 94% (98% ECO mode) | ||||
Power Factor | Up to PF 1 | ||||
Voltage (Vac) | 220/230/240 (L-N) 380/400/415 ± 1% (L-L), programmable | ||||
Frequency (Hz) | 50/60 ± 0.1% (on battery) | ||||
THDv | THD <2% (linear load), | ||||
THD <3% (nonlinear load) | |||||
Transfer Time (ms) | 0 | ||||
Overload | 125% for 10 min, 150% for 1 min | ||||
ECOMode | Yes | ||||
Battery | |||||
Voltage (Vdc) | ± 144 – 240Vdc programmable / 25% derating < 158Vdc | ||||
Built-in battery | 30x 12V17AH (5-year battery) | 40x 12V17AH (5-year battery) | |||
30x 12V20Ah FR (10-year battery) | 40x 12V20Ah FR (10-yearbattery) | ||||
Charging Current (A) | 4A(1-10A programmable) | 8A(1-20A programmable) | |||
12V VRL /1.2V Nicd | ± 12-20 block / ± 120-170 cells | ||||
Communication Interface | RS485 MODBUS + EPO + dry contact standard | ||||
TCP – IP / SNMP / RS232 option | |||||
Input / Output configuration | 11 / 31 / 33 | 31 / 33 | |||
Display | Blue touch screen | ||||
Alarm | Low battery, Abnormal AC input, UPS failure | ||||
Protection | Low battery, overload, short – circuit and over temperature, etc. | ||||
Noise (dB) | < 55 | ||||
Working Temperature | -5 ~ 40°C | ||||
Relative Humidity | ± 0 ~ 95%, No condensation | ||||
Dimension (hxwxd mm) | 1450 x 650 x 675 | 1450 x 780 x 860 | |||
Weight with battery (kg) | 280 | 315 | 325 | 410 | 435 |
International standards | IEC 62040-1, YD – T 1095-2018, GB / T 14715-2017 |